Applicable to the air leakage test of lens unit modules in automotive, security, smart home and other fields.
Process Flow:
Manuallly scan code of modules →manually load module onto jig→move jig to test workbench→NG products sorting prompt→manual receiving
Product Feature:
1.Selectable Single&dual-workbench models meet the requirements for different production capacity;
2.With dual-button activation,safety light curtain and other safeguards,manual operation is highly ergonomical;
3. Compatible with the air leakage test of multiple types of lens unit modules,adapted to various process requirements;
4. User-friendly interface;visualized data;smart operation.
| Equipment Model | CAMM-LEAK-1-01 | CAMM-LEAK-2-01 |
| Applicable Product | Applicable to PCBA and Holders of Security/Automotive/ADAS/DMS Products,etc(Rear Line Products Included). Compatible Size:<50*50*50mm | |
| Loading & Unloading Method | Manual | |
| Test Workbench Qty | 1 | 2 |
| Test Method | Indirect Test Method: Customized Tooling and Molds; Placing Camera Modules in Airtight Space and Test Air Leakage Value Via Air Pressure Change. | |
| Max Sealing Pressure | 550N | |
| Test Pressure | 10kPa~500kPa(Support Extension of Negative Pressure Test,-60kPa~0kPa) | |
| Sensor Resolution | 0.1Pa | |
| Code Scanning | Optional | |
| Compatible With Air Leakage Test Instruments |
COSMO/ATEQ/HIRAYS(Selectable as Needs) | |
| UPH | 100~120(Subject to Air Leakage Test Time) | 200~240(Subject to Air Leakage Test Time) |
| Overall Dimensions | 1000*1000*2200mm | 1100*1000*2200mm |
| Equipment Weight | 500KG | 550KG |
| Rated Power | 1.4KW | 1.5KW |
| Power Supply Requirement | AC220V/10A/50HZ | |
| Air Pressure Requirement | 0.4MPa~0.6MPa | |
| Environment Temperature | 10℃~30℃ | |
| Environment Humidity | ≤80% No Condensation | |